TY - JOUR
T1 - Evaluation of reverse transcription-PCR assays for rapid diagnosis of severe acute respiratory syndrome associated with a novel coronavirus
AU - Yam, W. C.
AU - Chan, K. H.
AU - Poon, L. L.M.
AU - Guan, Y.
AU - Yuen, K. Y.
AU - Seto, W. H.
AU - Peiris, J. S.M.
PY - 2003/10/1
Y1 - 2003/10/1
N2 - The reverse transcription (RT)-PCR protocols of two World Health Organization (WHO) severe acute respiratory syndrome (SARS) network laboratories (WHO SARS network laboratories at The University of Hong Kong [WHO-HKU] and at the Bernhard-Nocht Institute in Hamburg, Germany [WHO-Hamburg]) were evaluated for rapid diagnosis of a novel coronavirus (CoV) associated with SARS in Hong Kong. A total of 303 clinical specimens were collected from 163 patients suspected to have SARS. The end point of both WHO-HKU and WHO-Hamburg RT-PCR assays was determined to be 0.1 50% tissue culture infective dose. Using seroconversion to CoV as the "gold standard" for SARS CoV diagnosis, WHO-HKU and WHO-Hamburg RT-PCR assays exhibited diagnostic sensitivities of 61 and 68% (nasopharyngeal aspirate specimens), 65 and 72% (throat swab specimens), 50 and 54% (urine specimens), and 58 and 63% (stool specimens), respectively, with an overall specificity of 100%. For patients confirmed to have SARS CoV and from whom two or more respiratory specimens were collected, testing the second specimen increased the sensitivity from 64 and 71% to 75 and 79% for the WHO-HKU and WHO-Hamburg RT-PCR assays, respectively. Testing more than one respiratory specimen will maximize the sensitivity of PCR assays for SARS CoV.
AB - The reverse transcription (RT)-PCR protocols of two World Health Organization (WHO) severe acute respiratory syndrome (SARS) network laboratories (WHO SARS network laboratories at The University of Hong Kong [WHO-HKU] and at the Bernhard-Nocht Institute in Hamburg, Germany [WHO-Hamburg]) were evaluated for rapid diagnosis of a novel coronavirus (CoV) associated with SARS in Hong Kong. A total of 303 clinical specimens were collected from 163 patients suspected to have SARS. The end point of both WHO-HKU and WHO-Hamburg RT-PCR assays was determined to be 0.1 50% tissue culture infective dose. Using seroconversion to CoV as the "gold standard" for SARS CoV diagnosis, WHO-HKU and WHO-Hamburg RT-PCR assays exhibited diagnostic sensitivities of 61 and 68% (nasopharyngeal aspirate specimens), 65 and 72% (throat swab specimens), 50 and 54% (urine specimens), and 58 and 63% (stool specimens), respectively, with an overall specificity of 100%. For patients confirmed to have SARS CoV and from whom two or more respiratory specimens were collected, testing the second specimen increased the sensitivity from 64 and 71% to 75 and 79% for the WHO-HKU and WHO-Hamburg RT-PCR assays, respectively. Testing more than one respiratory specimen will maximize the sensitivity of PCR assays for SARS CoV.
UR - http://www.scopus.com/inward/record.url?scp=0141993032&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0141993032&partnerID=8YFLogxK
U2 - 10.1128/JCM.41.10.4521-4524.2003
DO - 10.1128/JCM.41.10.4521-4524.2003
M3 - Article
C2 - 14532176
AN - SCOPUS:0141993032
SN - 0095-1137
VL - 41
SP - 4521
EP - 4524
JO - Journal of Clinical Microbiology
JF - Journal of Clinical Microbiology
IS - 10
ER -